The Role of Emergency Generator during Black-Out on the MV. Kelud

Peranan Emergency Generator saat Black-Out di Kapal KM. Kelud

Authors

  • Muhamad Nurji Setyo Utomo Politeknik Pelayaran Malahayati Author
  • Albert Wiweko Politeknik Pelayaran Malahayati Author
  • Muhammad Sapril Siregar Politeknik Pelayaran Malahayati Author https://orcid.org/0000-0002-5231-5990
  • Muhammad David Politeknik Pelayaran Malahayati Author
  • Eka Nurmala Politeknik Pelayaran Malahayati Author

DOI:

https://doi.org/10.62554/fk4ny376

Keywords:

Emergency Generator, Blackout, Main Engine, Overheating, Auxiliary Engine

Abstract

Emergency generator is an auxiliary machine that functions to generate electrical power to meet the electrical needs of the ship during an emergency (black-out). This research was conducted to find out what caused the black-out onboard KM. Kelud, how the role of the Emergency generator during a black-out, and how to maintain the emergency generator so that it is always ready when used. The research method that the author uses is a qualitative research method. Data collection is done through interviews and observations. The results obtained from this study indicate that the cause of the black-out on KM. Kelud is the entry of mud into the hull, causing the cooling system in the main engine to be disrupted and eventually black-out. The role of the emergency generator during a black-out is as a temporary source of electricity to run several devices, such as navigation equipment, ship lighting, fire alarm systems, sprinkle pumps, and watertight door systems. In order for the emergency generator to run according to its function, it must be carried out routine maintenance such as checking batteries, oil and lubricants, cooling systems, and periodic testing.

Downloads

Download data is not yet available.

Author Biographies

  • Albert Wiweko, Politeknik Pelayaran Malahayati

    Lecturer

  • Muhammad Sapril Siregar, Politeknik Pelayaran Malahayati

    Lecturer

  • Muhammad David, Politeknik Pelayaran Malahayati

    Lecturer

  • Eka Nurmala, Politeknik Pelayaran Malahayati

    Lecturer

References

Asy’ari, H., Handaga, B., Basith, A., & Himawan, M. A. (2016). Pengaruh Perbandingan Konstruksi Stator terhadap Tegangan Keluaran Generator Linier. Emitor: Jurnal Teknik Elektro, 16(1), 32–42. https://journals.ums.ac.id/index.php/emitor/article/view/2681

Faturachman, D., & Febrian, S. (2020). Studi Literatur Tinjauan Penggunaan Generator Package Set Darurat pada Sebuah Kapal. Jurnal Sains & Teknologi Fakultas Teknik Universitas Darma Persada, 10(1), 80–91. https://unsada.e-journal.id/jst/article/view/80

Indriani, A. (2015). Analisis Pengaruh Variasi Jumlah Kutub dan Jarak Celah Magnet Rotor terhadap Performan Generator Sinkron Fluks Radial. Electrician: Jurnal Rekayasa dan Teknologi Elektro, 9(2), 63–72. https://doi.org/10.23960/elc.v9n2.164

Julianto, E., & Sunaryo, S. (2020). Analisis Pengaruh Putaran Mesin pada Efisiensi Bahan Bakar Mesin Diesel 2Dg-Ftv. Jurnal Penelitian dan Pengabdian Kepada Masyarakat UNSIQ, 7(3), 225–231. https://doi.org/10.32699/ppkm.v7i3.1282

Julianto, T. (2016). Pemanfaatan Perbedaan Temperatur pada Main Engine Cooling System sebagai Energi Alternatif untuk Pembangkit Listrik di Kapal. Jurnal Teknik ITS, 5(2), B419–B423. 10.12962/j23373539.v5i2.19434

Mustain, I., & Abdullah, U. (2020). Penurunan Tekanan pada Pompa Air Laut pada Mesin Induk Kapal. Majalah Ilmiah Gema Maritim, 22(1), 27–33. https://doi.org/10.37612/gema-maritim.v22i1.48

Nst, M. M. (2023). Analisis Kapasitas dan Kebutuhan Daya Listrik untuk Menghemat Penggunaan Listrik di Kapal. Journal of Maritime and Education (JME), 5(2), 534–540. https://doi.org/10.54196/jme.v5i2.113

Paseru, J. U., Bakar, A., & Syahrisal, S. (2019). Analisis Tidak Normalnya Diesel Engine Pembangkit Listrik (Generator) sehingga Mengakibatkan Black Out di MT. Eleanor 1. Jurnal Karya Ilmiah Taruna Andromeda, 3(8), 113–130. https://jurnal.pipmakassar.ac.id/index.php/ard/article/view/503

Pratama, A. A., Astriawati, N., Waluyo, P. S., & Wahyudiyana, R. (2022). Optimalisasi Perawatan Sistem Pendingin Mesin Utama di Kapal MV. Nusantara Pelangi 101. Majalah Ilmiah Bahari Jogja, 20(1), 1–11. https://doi.org/10.33489/mibj.v20i1.289

Sarwito, S., Kusuma, I. R., & Waramory, B. H. (2016). Design of Automatic Transfer Switch ACOS with Human Machine Interface Monitoring System in Shipboard Application. International Journal of Marine Engineering Innovation and Research, 1(1). http://dx.doi.org/10.12962/j25481479.v1i1.1388

Siregar, M. (2022). Principal Managerial Competency in Learning Quality Improvement. Jurnal Curere, 6(1), 104–112. http://dx.doi.org/10.36764/jc.v6i1.718

Siregar, M. S., & Hartati, D. V. (2023). Pengoperasian Dynamic Positioning System di Kapal PSV. WM Sulawesi saat Snatching pada Drillship GSF Explorer. Airman: Jurnal Teknik dan Keselamatan Transportasi, 6(2), 189–198. https://doi.org/10.46509/ajtk.v6i2.413

Subekti, J., Wibowo, W., Astriawati, N., & Fadholy, M. H. (2022). Optimalisasi Perawatan Sistem Pendingin Mesin Utama Tipe Hansin Glu28ag pada Kapal. Dinamika Bahari, 3(1), 60–68. https://doi.org/10.46484/db.v3i1.303

Sugiyono, S., & Lestari, P. (2021). Metode Penelitian Komunikasi (Kuantitatif, Kualitatif, dan Cara Mudah Menulis Artikel pada Jurnal Internasional). Alvabeta Bandung, CV. https://tinyurl.com/2f92xt74

Sunarlik, W. (2011). Prinsip Kerja Generator Sinkron. Jurnal November. https://updkediri.ac.id/wp-content/uploads/2014/06/Prinsip-Kerja-Geneator-Sinkron-.pdf

Wibowo, W., Astriawati, N., & Jamaluddin, J. (2021). Optimalisasi Perawatan Sistem Pendingin Tertutup pada Mesin Diesel Tipe MAK 8M32 pada KM. Lit Enterprise. J. Polimesin, 19(1), 28–34. https://tinyurl.com/5n6n224v

Downloads

Published

2024-05-24

How to Cite

The Role of Emergency Generator during Black-Out on the MV. Kelud: Peranan Emergency Generator saat Black-Out di Kapal KM. Kelud. (2024). ALTAIR: Jurnal Transportasi Dan Bahari, 1(1), 9-20. https://doi.org/10.62554/fk4ny376