Analysis of Freon Leakage in Condenser to Room Temperature on MT. Kuang

Analisa Kebocoran Freon pada Kondensor terhadap Suhu Ruangan di Kapal MT. Kuang

Authors

  • Iqbal Muhammad Ardy Politeknik Pelayaran Malahayati Author
  • Albert Wiweko Politeknik Pelayaran Malahayati Author
  • Muhammad Sapril Siregar Politeknik Pelayaran Malahayati Author https://orcid.org/0000-0002-5231-5990
  • Eka Nurmala Politeknik Pelayaran Malahayati Author
  • Dinur Syahputra Universitas Battuta Author

DOI:

https://doi.org/10.62554/d0w1yv20

Keywords:

Freon, Condensor, Temperature, Room, Vessel

Abstract

The development of technology has led to increased use of air conditioning. Air conditioning is a process that cools, dries, cleans, and circulates air, while controlling its quantity and quality. It is important for machinists and electricians responsible for cooling machines to effectively carry out their duties and responsibilities by maintaining the machines properly. This research is a qualitative case study involving descriptive analysis using written or spoken observations of behavior. It focuses on the analysis of freon leaks in the condenser related to room temperature on the MT ship, Kuang. The research concludes that the decrease in condenser work in refrigerator machines is caused by interference with the dryer. The recommended efforts include inspecting and repairing leaking pipes, and conducting maintenance and repairs in accordance with the Manual Book standards.

Downloads

Download data is not yet available.

Author Biographies

  • Albert Wiweko, Politeknik Pelayaran Malahayati

    Lecturer

  • Muhammad Sapril Siregar, Politeknik Pelayaran Malahayati

    Lecturer

  • Eka Nurmala, Politeknik Pelayaran Malahayati

    Lecturer

  • Dinur Syahputra, Universitas Battuta

    Lecturer

References

Anwar, K. (2010). Efek Beban Pendingin terhadap Performa Sistem Mesin Pendingin. SMARTek, 8(3). http://jurnal.untad.ac.id/jurnal/index.php/SMARTEK/article/view/640/556

Firdiansyah, B. N., & Riyadin, F. (2024). Pembuatan Kondesor Tube in Tube dengan Metode Pengelasan Tig pada Kapal Selam Wisata Golden Manta. Scientica: Jurnal Ilmiah Sains Dan Teknologi, 2(3), 142–158. https://doi.org/10.572349/scientica.v2i3.1093

Herlina, Y., & Hadiyani, T. (2021). Pentingnya Menjaga Perawatan Central Air Conditioner sesuai Petunjuk Manual Book di Kapal MV. Tuna Queen. Majalah Ilmiah Gema Maritim, 23(1), 7–14. https://doi.org/10.37612/gema-maritim.v23i1.114

Khoirotun, A., Fianto, A. Y. A., & Riqqoh, A. K. (2014). Perancangan Buku Pop-Up Museum Sangiran sebagai Media Pembelajaran tentang Peninggalan Sejarah. Universitas Dinamika. https://media.neliti.com/media/publications/248040-perancangan-buku-pop-up-museum-sangiran-fa59e3c1.pdf

Nawawi, C. I., Nugroho, A. A., & Febrilianto, Y. (2022). Optimalisasi Kinerja Fresh Water Generator untuk Meningkatkan Produksi Air Tawar di atas Kapal. Journal Marine Inside, 45–54. https://doi.org/10.56943/ejmi.v4i1.42

Peramutya, A. D., Santoso, R., & Dinata, M. P. (2020). Pengaruh Terganggunya Sirkulasi Freon terhadap Mesin Pendingin di KMP. Lakaan. Journal Marine Inside, 2(2), 46–55. https://doi.org/10.56943/ejmi.v2i2.22

Prasetyo, G. R. D., Narto, A., & Sulistiyowati, E. (2024). Optimalisasi Perawatan Air Conditioner guna Menjaga Suhu Udara di Ruang Akomodasi pada Kapal MT. Tanker Lineo 101. Indonesian Journal of Marine Engineering, 1(1), 41–45. https://doi.org/10.46484/ijme.v1i1.570

Putra, A., Mukhnizar, M., Abu, R., Zulkarnain, Z., & Azman, A. (2023). Analisis Penyebab Turunnya Kinerja Kompresor untuk Tindakan Perawatan pada Kapal Tanker MT. Sea Serenity. Jurnal Teknik Industri Terintegrasi (JUTIN), 6(4), 1652–1658. https://doi.org/10.31004/jutin.v6i4.22358

Putri, S. W. K., Yushardi, Y., & Supriadi, B. (2018). Analisis Variasi Tipe Kondensor Air Conditioning (AC) terhadap Besar Peningkatan Suhu yang Dihasilkan. Jurnal Pembelajaran Fisika, 7(3), 293–298. https://doi.org/10.19184/jpf.v7i3.8603

Ridwan, M., Yuherlina, R., & Putra, D. A. (2020). Analisa dan Penanganan Terjadinya Penurunan Kevakuman pada Kondensor Utama terhadap Kinerja Turbin Uap di Kapal LNG. In Prosiding Seminar Pelayaran dan Teknologi Terapan (Vol. 2, pp. 130–139). https://doi.org/10.36101/pcsa.v2i1.134

Siregar, M. S. (2022). Kompetensi Manajerial Kepala Sekolah dalam Peningkatan Mutu Pembelajaran. Curere, 6(1), 104–112. http://dx.doi.org/10.36764/jc.v6i1.718

Siregar, M. S., & Hartati, D. V. (2023). Pengoperasian Dynamic Positioning System di Kapal PSV. WM Sulawesi saat Snatching pada Drillship GSF Explorer. Airman: Jurnal Teknik Dan Keselamatan Transportasi, 6(2), 189–198. https://doi.org/10.46509/ajtk.v6i2.413

Sukmanadjati, N. (2022). Optimalisasi Perawatan Mesin Pendingin Ruangan untuk Mempertahankan Suhu dalam Ruangan di Kapal Latih Politeknik Pelayaran Sorong. JPB: Jurnal Patria Bahari, 2(1). https://doi.org/10.54017/jpb.v2i1.52

Triyanto, A., & Ulinuha, S. T. A. (2021). Analisis Gangguan Hubung Singkat untuk Penentuan Breaking Capacity Circuit Breaker pada Sistem Distribusi PLTD di Pusat Pengembangan Sumber Daya Manusia Minyak dan Gas Bumi Cepu (Doctoral dissertation, Universitas Muhammadiyah Surakarta). https://eprints.ums.ac.id/93094/

Downloads

Published

2024-05-27

How to Cite

Analysis of Freon Leakage in Condenser to Room Temperature on MT. Kuang: Analisa Kebocoran Freon pada Kondensor terhadap Suhu Ruangan di Kapal MT. Kuang. (2024). ALTAIR: Jurnal Transportasi Dan Bahari, 1(1), 28-37. https://doi.org/10.62554/d0w1yv20